To set the power usage threshold, the power pairs to use, and the power detection method to use, select a single Nortel Ethernet Routing Switch 5520 unit.
|
Note: These parameters only can be viewed and set by selecting a single unit. If more than one unit is selected, the PoE tab is not displayed. |
To open the PoE tab for a single unit:
Procedure steps
|
|
|
| Step | Action |
|---|---|
|
|
|
| 1 |
From the navigation tree, double-click Edit. |
| 2 |
From the Edit tree, double-click Unit. |
| 3 |
Select the PoE tab. |
|
|
|
| --End-- | |
|
|
|
The following table outlines the parameters of the PoE tab.
Variable definitions
| Variable | Value | |
|---|---|---|
| Power | Displays the total power available to the Nortel Ethernet Routing Switch 5520. | |
| OperStatus |
Displays the power state of the Nortel Ethernet Routing Switch 5520.:
|
|
| Consumption Power |
Displays the power being used by the Nortel Ethernet Routing Switch 5520. | |
| Usage Threshold |
Enables you to set a percentage of the total power usage of the Nortel Ethernet Routing Switch 5520 switch based on which the system sends a trap.
|
|
| Notification Control Enable |
Enables you to enable or disable sending traps if the switch’s power usage exceed the percentage set in the UsageThreshold field. | |
| PowerDevice DetectType |
Enables you to set the power detection method that the switch uses to detect a request for power from a device connected to all ports on the switch:
|
|
| PowerPairs | Displays the RJ-45 pin pairs that the switch uses to send power to the ports on the switch. |