To configure AUR:
Procedure steps
|
|
|
| Step | Action |
|---|---|
|
|
|
| 1 |
From the navigation tree, double-click Edit. |
| 2 |
From the Edit tree, double-click Chassis. |
| 3 |
From the Chassis tree, double-click Chassis. |
| 4 |
Select the AUR tab. |
| 5 |
Enable Auto Unit Replacement by selecting the AutoUnitReplacementEnabled check box. |
| 6 |
Enable Auto Unit Replacement saving by selecting the AutoUnitReplacementSaveEnabled check box. |
| 7 |
Enter a value for forced saves in the AutoUnitReplacementForceSaves field. |
| 8 |
Enter a value for AUR restore in the AutoUnitReplacementRestore field. |
| 9 |
Click Apply. |
|
|
|
| --End-- | |
|
|
|
The following table outlines the parameters for the AUR tab.
Variable definitions
| Variable | Value |
|---|---|
| AutoUnitReplacementEnabled | Specifies whether AUR is enabled. |
| AutUnitReplacementSaveEnabled | Specifies whether AUR Save is enabled. |
| AutUnitReplacementForceSave | Specifies whether an immediate save of the new base unit (NBU) configuration to the base unit (BU) is forced. |
| AutUnitReplacementRestore | Specifies whether the configuration of a unit from the saved configuration on the base unit is restored. |