Use the following procedure to configure the end of a time interval for the switch to enter lower power states. The time interval can span a complete week, a complete weekend, multiple days, or be configured within an individual day.
Prerequisites
Procedure steps
|
|
|
| Step | Action |
|---|---|
|
|
|
| 1 |
From the navigation tree, double-click Power Management. |
| 2 |
In the Power Management tree, double-click Energy Saver. |
| 3 |
In the work area, click the Energy Saver Schedules tab. |
| 4 |
Click Insert. |
| 5 |
To choose a day for the NES schedule off time, select a button in the ScheduleDay section. |
| 6 |
To choose an hour of the day for the NES schedule off time, type a value in the ScheduleHour box. |
| 7 |
To choose a portion of an hour for the NES schedule off time, type a value in the ScheduleMinute box. |
| 8 |
To configure the selected day, hour, and minutes as the NES schedule off time, click the deactivate radio button in the ScheduleAction section. Activate is selected by default. |
| 9 |
Click Insert. |
|
|
|
| --End-- | |
|
|
|
The following table describes the fields of Insert Energy Saver Schedule window.
Variable definitions
| Variable | Value |
|---|---|
| ScheduleDay | Indicates the day on which this schedule entry takes effect. |
| ScheduleHour | Indicates the hour on which this schedule entry takes effect. |
| ScheduleMinute | Indicates the Minute on which this schedule entry takes effect. |
| ScheduleAction | Activates or deactivates the energy savings. |