To view the Globals - PoE Units tab:
Procedure steps
|
|
|
| Step | Action |
|---|---|
|
|
|
| 1 |
From the navigation tree, double-click Power Management. |
| 2 |
From the Power Management tree, double-click PoE. |
| 3 |
Select the Globals - PoE Units tab. |
|
|
|
| --End-- | |
|
|
|
The following table outlines the parameters of the Globals - PoE Units tab.
Variable definitions
| Variable | Value |
|---|---|
| Unit | Specifies the unit number in the stack. |
| Power(watts) | Specifies the power in Watts. |
| OperStatus | Specifies whether PoE is enabled |
| ConsumptionPower(watts) | Specifies the power consumption in Watts. |
| UsageThreshold% | Specifies the usage threshold expressed as a percentage for comparing the measured power and initiating an alarm if the threshold is exceeded. |
| NotificationControlEnable | Controls, on a per-group basis, whether or not notifications from the agent are enabled. The value true(1) means that notifications are enabled; the value false(2) means that they are not. |
| PoweredDeviceDetectType | Specifies the mechanism used to detect powered ethernet devices attached to a powered ethernet port. This object should only be instantiated for values of ifIndex that represent ports that support powered ethernet. |