Use this procedure to configure the start or end of a time interval
for the switch to enter lower power states. The time interval can
span a complete week, a complete weekend, multiple days, or be configured
within an individual day.
Before you begin
Disable AES
globally
Procedure
From the navigation
tree, double-click Power Management.
In the Power Management
tree, click Energy Saver.
In the work area, click
the Energy
Saver Schedules tab.
Click Insert.
To choose a day for
the AES schedule on time, click a button in the ScheduleDay section.
To choose an hour of
the day for the AES schedule on time, type a value in the ScheduleHour box.
To choose a portion
of an hour for the AES schedule on time, type a value in the ScheduleMinute box.
To configure the selected
day, hour, and minutes as the AES schedule on time, click the activate button in the ScheduleAction section.
Activate is selected by default.
To configure the selected
day, hour, and minutes as the AES schedule off time, click the deactivate button in the ScheduleAction section.
Click Insert.
Variable Definitions
The following table describes the fields of Insert Energy Saver Schedule window.
Variable
Value
ScheduleDay
Indicates the day on which this schedule entry takes effect.
ScheduleHour
Indicates the hour on which this schedule entry takes effect.
ScheduleMinute
Indicates the Minute on which this schedule entry takes effect.