IPFIX collectors are used to collect and analyze data exported from an IPFIX-compliant switch. Up to two collectors can be supported.
The switch exports IPFIX data in Netflow version 9 format using UDP port 9995.
IPFIX data is not load balanced when two collectors are in use. Identical information is sent to both collectors.
Use the following procedures to configure an IPFIX collector.
The following table describes the fields of the Insert Collectors dialog.
| Field | Description |
|---|---|
| Slot | Indicates the unit number of the collector. Currently up to two collectors are supported so the values 1 or 2 are valid. |
| AddressType | Indicates the address type of the IP address of the collector. Currently only IPv4 addresses are supported. |
| Address | Indicates the IP address of the collector. |
| Protocol | Indicates the protocol used to transport the IPFIX data to the collector. Currently only the UDP protocol is supported for this task. |
| DestPort | Indicates the port on which the collector is listening for IPFIX data. Currently only port 9995 is supported for this task. |
| ProtoVer | Indicates the format in which IPFIX data is provided to the collector. Currently only Netflow version 9 formatting is supported for this task. |
| Enable | Indicates the operational state of this collector. |
The following table describes the fields of Collectors tab.
| Field | Description |
|---|---|
| Slot | Indicates the unit number of the collector. Currently up to two collectors are supported. |
| AddressType | Indicates the address type of the IP address of the collector. Currently only IPv4 addresses are supported. |
| Address | Indicates the IP address of the collector. |
| Protocol | Indicates the protocol used to transport the IPFIX data to the collector. Currently only the UDP protocol is supported for this task. |
| DestPort | Indicates the port on which the collector is listening for IPFIX data. Currently only port 9995 is supported for this task. |
| ProtoVer | Indicates the format in which IPFIX data is provided to the collector. Currently only Netflow version 9 formatting is supported for this task. |
| Enable | Indicates the operational state of this collector. |