Use the following procedure to configure Stack Monitor using EDM.
Open one of the supported browsers.
Enter the IP address of the switch to open an EDM session.
From the navigation tree, double-click Edit.
In the Edit tree, double-click Chassis.
In the Chassis tree, double-click Chassis.
In the work area, click the Stack Monitor tab.
In the Stack Monitor tab, configure the required parameters.
On the toolbar, click Apply.
The following table describes the fields of Stack Monitor tab.
| Field | Description |
|---|---|
| StackErrorNotificationEnabled | Enables or disables the Stack Monitoring feature. |
| ExpectedStackSize | Specifies the size of the stack to monitor. Valid range is 2–8. Default value is 2. |
| StackErrorNotificationInterval | Specifies the time interval between traps, in seconds. Valid range is 30–300 seconds. Default value is 60. |
| StackRebootUnitOnFailure | Enables or disables the rebooting stack units on failure. |
| StackRetryCount | Sets the retry count for the stack. |